0

50kVA / 62.5kVA Diesel Generator Set

50kVA / 62.5kVA Diesel Generator Set
Product Description

We have been serving our respected clients since 1985 by manufacturing and supplying excellent quality 50kVA / 62.5kVA Diesel Generator Set. These are manufactured using optimum quality components and cutting-edge technology in line with the set industry standards. Known for its low noise operation, high performance and long service life, we offer this 50kVA / 62.5kVA Diesel Generator Set to our precious clients at reasonable rates. Owing to our efficient logistics system, we deliver our products in a promised time.  

Features:

  • Rugged build quality

  • Finished with rust proof coating

  • Long lasting maintenance free life

 

 

Technical Specifications :

Genset Rating (kVA)

50

62.5

Power Rating (kW)

40

50

No. of Phases

3 Phase

3 Phase

Output Voltage (V)

415V

415V

Power Factor (lagging)

0.8

0.8

Current (A) (1phase / 3 phase)

70

104

Frequency (Hz) RPM

50/1500

50/1500

Governing Class

A1

A1

Starting system

12V DC Electrical

12V DC Electrical

Fuel tank capacity (lit)

200

200

Genset dimensions (L x W x H) (mm) approx

2800x1150x1535

2800x1150x1535

Genset weight (kg)

1260

1280

Engine Specifications :

Make

Mahindra

Mahindra

Model

4525 GMAC2

4905 GMAC2

Power Output (HP)

72

90

Aspiration

TCI

TCI

No. of cylinders

4

4

Bore x Stroke (mm)

94X115

96X122

Displacement (cc)

3192

3.5

Fuel consumption @ 75% load (lit/hr)

9.5

11.3

Fuel consumption @ 100% load (lit/hr)

12.4

15.3

Lube oil specification

SAE15W40 CH4

SAE15W40 CH4

Total lube oil system capacity (liter)

10

10

Lube oil consumption (lit/hr)°

0.15% of Fuel consumption

0.15% of Fuel consumption

Lube oil change period (hrs.)

300 hrs. for oil to up. 600 hrs. for oil change

300 hrs. for oil to up. 600 hrs. for oil change

Radiator coolant capacity (liters)

12

15

Alternator Specifications

Make

Mahindra Powerol

Mahindra Powerol

Enclosure Type

IP23

IP23

Voltage regulation

+1%

+1%

Class of insulation

Clase H

Clase H

Maximum Unbalanced Load across Phases

25%

25%

Notes :

  • Above specifications are subject to change without prior notice due to continuous product improvement
  • All Engines & alternators conform to respective IS standards
  • All the genset specifications conform to ISO 8528 Standard
  • height without sliencer
  • Fuel- High speed Diesel (HSO IS 1460 : 2005)
  • Considering 0.845 specific gravity of diesel, 5% tolerance
  • $Considering 0.89 specific gravity of oil.
  • All specifications are at standard NTP operating conditions
  • Engine power output 110% load
Contact Us

Shop No. 15, K. P. Complex, Barve Compound, Navapur Road, Boisar, Maharashtra, 401501, India
Phone :+918068216888